A range of components to provide ventilation over the fascia or through the soffit area. Over fascia ventilation is also available with eaves protection.

 
   

Certification

BBA Certification

 

 

 

Ventilation

*Ventilation Requirements

 


Range Notes
 Over Fascia Ventilators available in 10mm (C504) or 25mm (C505) continuous air path versions. 
 Vented Eaves Protector (C404) provides 10mm continuous air path ventilation and eaves protection. A Bird Comb (C405) attaches to C404 and provides a barrier to large insects and birds underneath the eaves tiles.
 Jumbotec provides eaves protection only.
   

Range Information:

Characteristics
 Rigid components in extruded or moulded format.
 All over fascia components are fixed to the top of the fascia board and are capable of bearing the weight of the eaves course of tiles.
 
   

 
 
 

Important Design and Installation notes:
 
Over Fascia
 Where Over fascia Ventilator (C504/505) and Vented Eaves Protector (C404) are specified the fascia height must be reduced.
          C404 - reduce fascia height by 25mm
          C504 - reduce fascia height by 22mm 
          C505 - reduce fascia height by 51mm
 Installation of an eaves protection unit will significantly increase the life expectancy of the installation. The rear flange of the unit must dress under the existing felt edge. (Fig1)
 Where a capping fascia is employed ensure that any ventilation or protection units are fixed into the top of the backing board only.
 Where eaves protection is not to be fitted the roof felt must be in good condition and dressed over the fascia down into the gutter (Fig7). In the case of severe deterioration, the roofing felt may require complete replacement.
 
Through Soffit
Ventilation may be provided via:
 Pre-vented boards ie Polo flat boards (Fig6) or cladding (Fig16). See Soffits Installation Guide.
 A combination of flat board (or cladding) and ventilation strips (Figs19/21).
 A circular ventilator is available where it is necessary to provide ventilation through an existing flat board soffit.
   

View Images

 
 
 
 
CAD Library
DXF & DWG drawings of Individual profiles and typical installed conditions 
 
 
 
Important Information

 


Installation Sequence
 Soffit Ventilation - Follow the installation process for soffits and fascias ensuring that allowance has been made for the height of any ventilation /protection unit.
 Over Fascia Ventilation - Fix over fascia ventilators to the top of the fascia with 65mm ringshanked galvanised steel nails and dress the roofing felt over the top of the ventilator/protection unit.
   