Swish Building Products limited

For Construction Professionals

search site

about us | contact us | find us

  • home
  • products
  • design
  • installation
  • environmental
  • library
  • customers
  • talk to us
  • vacancies
 
Swish Approved Installers – Sign In

Products

  • fascias
  • soffits
  • decorative fascias & trims
  • eaves & vents
  • guttering
  • cladding
  • gallows & dentils
  • window boards, trims and reveals
  • foiled finishes
  • self colours


Ask about installation.

Please insert your question and details here:


Please type the letters and numbers shown in the image.
 
Captcha Code

Click the image to see another captcha.


 
home > installation

Installation

Training videos, information packs and knowledge tests for professional and trainee installers of PVC fascias, soffits, gutters and cladding.

  • Range Guide
  • Roofline Design & Installation
  • Cladding Design & Installation
  • Video Trainer
  • Installation Guides
  • Building Regs
  • The Range
  • Knowledge Tester
  • Find a Stockist

Fascia and Soffit Installation Training Film

This film is for fascia installers who wish to understand the basic techniques and methods used to fit new cellular PVC fascias and soffits. Swish regards Safety and Quality as the most important factors in any fascia installation.

Run Time : 12 minutes 53 seconds
Commentary : Includes voiceover

The absence or variation from a technique shown in this film does not nesccessarily mean that a fault is being committed.
If any clarification or further information is required please contact Swish Technical Services on 01827 317200.

Notes

  • Swish recommends that installers follow industry best practice and fully replace existing fascia and soffit boards.
  • Swish also recommends the use of a full scaffold system or a properly configured cantilever decking system.
  • The installation techniques show in this film represent some of those most commonly used by Swish Approved Installers.
  • Some installers use treated timber or sound sections of timber from the existing roofline inorder to create the fascia and soffit hangers shown in the film.

Installation Guides

Click on the guide you require. It will open in the Swish document viewer.

Swish-Roofline-Design-Guide.jpg

Roofline
Design Guide

Swish-Claddings-Design-Guid.jpg

Cladding
Design Guide

Swish Product-Bulletin-Foiled-Cladding Installation.jpg

Important
Foiled & Coloured
Cladding Guidelines

 
 

Ventilation at the Eaves

Roof voids must be ventilated at the eaves in order to stop warm air condensing on cold surfaces. Condensation encourages rot and mould growth. The air gap dimensions shown are the minimum required for clear continuous air paths at the eaves.

*Duo pitch roofs greater than 200 pitch or greater than 10m span should have additional ventilation at the ridge to assist airflow through the roof void, equivalent to at least a 3 mm wide continuous gap. Additionally, if the span is greater than 10m the overall ventilation area should be increased to at least 0.6% of the total roof area.
**Air paths should not be obstructed. A minimum 50mm free air path should be maintained between the top of the insulation and the underside of the roof decking.

Ventilators

Swish ventilators for roof voids are covered by British Board of Agrément Certificate No.91/2620. When used in accordance with the Certificate, Swish ventilators will satisfy the following statutory requirements.

England and Wales

The Building Regulations 2000 (as amended) (England and Wales):
Requirement C2 (a) (b) (c): Resistance to Moisture
Regulation 7: Materials and workmanship.

Scotland

The Building (Scotland) Regulations 2004: (as amended)
Regulation 8: (1) (2) Fitness and durability of materials and workmanship
Regulation 9: Building Standards – Construction; Standard 3.10 – Precipitation and Standard 3.15 - Condensation

Northern Ireland

The Building Regulations (Northern Ireland) 2000, Regulation B2; (as amended)
Fitness of materials and workmanship, C4: (b) Resistance to ground moisture and weather and C5: Condensation.

Swish ventilators also meet the recommendations BS 5250: 2002 which deals comprehensively with the subject of condensation in dwellings.

Know the Range

These tabs hold a quick overview of the Swish fascia, soffit, gutter and cladding product ranges and the main functions of each range.

  • Guttering
  • Fascias & Bargeboards
  • Soffits
  • Ventilation
  • Cladding
  • Decorative
  • Colours

A full range of domestic and light commercial Gutter systems that are made from a high proportion of recycled material. This means that there is a significant reduction in CO2 output during manufacture.

Round

Swish-Round-Gutter-250px.jpg

A traditional half round gutter suitable for application on terrace houses, semi-detached houses and smaller office and commercial buildings.

Specification – Gutter Laid Level

Max. height of water

48mm

Short length gutter

2.4m

Flow rate of short gutter

0.84 l/s

Max. area drained – End outlet

40 m2

Max. area drained – Mid outlet

80 m2

Down pipe

Round

 

 

 

Specification – Gutter Laid Level
Max. height of water 48mm
Short length gutter 2.4m
Flow rate of short gutter 0.84 l/s
Max. area drained* – End outlet 40 m2
Max. area drained* – Mid outlet 80 m2
Down pipe Round

Square

Swish-Square-Gutter-250px.jpg

Classic square system equally suitable for modern or older housing and often used on conservatories. The higher flow rate has the capacity to drain larger roofs.

Specification – Gutter Laid Level

Max. height of water 56mm
Short length gutter 2.7m
Flow rate of short gutter 1.2 l/s
Max. area drained – End outlet 56 m2
Max. area drained – Mid outlet 112 m2
Down pipe Square/Round

 

 

 

Specification – Gutter Laid Level
Max. height of water 48mm
Short length gutter 2.4m
Flow rate of short gutter 0.84 l/s
Max. area drained* – End outlet 40 m2
Max. area drained* – Mid outlet 80 m2
Down pipe Round

Ogee

Swish-Ogee-Gutter.jpg

A modern, high capacity system ideal for larger roofs and where run off is rapid. May be hung on traditional brackets or secretly fixed with top hung brackets when clean lines are important. A choice of corner angles that are positively fixed for added security

Specification – Gutter Laid Level

Max. height of water 68mm
Short length gutter 3.4m
Flow rate of short gutter 1.8 l/s
Max. area drained – End outlet 85 m2
Max. area drained – Mid outlet 170 m2
Down pipe Round/Square

 

 

 

Specification – Gutter Laid Level
Max. height of water 48mm
Short length gutter 2.4m
Flow rate of short gutter 0.84 l/s
Max. area drained* – End outlet 40 m2
Max. area drained* – Mid outlet 80 m2
Down pipe Round

Deep Flow

Swish-Deepflow-Gutter-250px.jpg

A high capacity round system for larger houses and accomodation blocks. The higher flow rate is espcially suitable for draining larger roof areas.

Specification – Gutter Laid Level

Max. height of water 69mm
Short length gutter 3.4m
Flow rate of short gutter 1.3 l/s
Max. area drained – End outlet 62 m2
Max. area drained – Mid outlet 124 m2
Down pipe Round

 

 

 

Specification – Gutter Laid Level
Max. height of water 48mm
Short length gutter 2.4m
Flow rate of short gutter 0.84 l/s
Max. area drained* – End outlet 40 m2
Max. area drained* – Mid outlet 80 m2
Down pipe Round

Bullnose Jumbo.jpg  Ogee Jumbo.jpg  Square Jumbo.jpg

pdf-version-icon.gifReplacement fascia boards

Swish Jumbo fascia boards and Swish foiled boards do not require a timber backing board. They are fixed directly to the rafter foot and bear the weight of guttering and eaves tiles. BBA Certificate No 91/2620

M-Boss

A range of square fascia profiles embossed with a decorative grained finish.  M-Boss provides the perfect combination of low-maintenance, cellular PVC with a traditional timber-like appearance.

All-16mm-Fascias.gif

16mm Replacement fascia boards

Swish 16mm fascia boards and their foiled versions do not require a timber backing board. They are fixed directly to the rafter foot and bear the weight of guttering and eaves tiles.

All-cappit.gif

Over-capping boards

Cappit and Ogee Cappit can be fitted over the face of sound existing timber components but are not load bearing in respect of gutters and eaves tiles.

All-Dec-Barges.gif

Decorative Bargeboards

There are two Swish systems:
 
i) Decorative Roofline consists of concave and convex designs in 5m lengths.
ii) Roofstyle is a system of moulded 450mm components (convex & concave) that fit to the face of an existing board.

GeePee-and-Fluted.gif

pdf-version-icon.gifGee Pee Flat Boards
Unventilated 9mm thick soffit boards.   Profiles are available with 2 finished edges or one sawn edge.  Deeper soffits can be constructed using joint strip C041.
A fluted 300mm unit allows creation of a planking effect.

Polo-10-and-25.gif

Polo Ventilated Boards
Boards comply with UK Building Regulations for new build and replacement applications and provides the equivalent of either a 10mm or 25mm air path.  Boards are 9mm thick.  Deeper soffits can be constructed using joint strips.

opev-and-teegee-as-soffit.gif

Cladding as Soffit
Open V and Tee Gee cladding profiles are often used as soffit boards where enhanced detailing is required across a large area e.g. a porch ceiling or overhang.

Vented-Cladding.gif

Ventilated Cladding
PoloTM ventilated Open V and Tee GeeTM cladding facilitate the creation of deep soffits. Profiles offer the equivalent of a 10mm continuous air path.

Joint-and-trim.gif

Joints & Vent Strips
A range of general purpose vented and unvented trims catering for jointing soffit sections and supporting soffits at wall junctions.

Vent-Strips.gif

Building regulations require the roof void to be ventilated according to the pitch and shape of the roof covering.

Ventilation is required to prevent the build up of condensation with consequential damage from rot. Ventilation may be provided through the soffit or over the fascia. Go to Building Regulations for details.

Over Fascia Ventilatiors

Where a clean soffit is required Swish Over Fascia Ventilator (C504/505) and Swish Vented Eaves Protector (C404) provide over-fascia ventilation and protection for new build and refurbishment projects.

Vented Soffit Boards

Polo 9mm GeePee ventilated flat board for soffits. Available with equivalent 10mm or 25mm continuous air gap. Sizes range from 150mm to 605mm. Deeper soffits can be constructed using joint strips.
Vented Cladding
Polo vented Open V and TeeGee cladding profiles with equivalent 10mm continuous air path. Use with standard cladding as soffit boards where enhanced detailing is required across a large area eg. porch ceiling.

Vent Strips

A range of vented trims for jointing soffit sections, and supporting soffits at the wall.

Circular Ventilator

Where the existing soffits are to be retained, the Swish C267 circular soffit ventilator is available for insertion into the soffit board.

A full range of robust cladding profiles in traditional styles, with complementary joints, trims and fixings.

Swish cellular PVC cladding is an ideal substitute for timber in that it will not discolour with time, retains its appearance, is virtually maintenance free and is weather resistant.
In addition, cellular PVC cladding can significantly improve the thermal performance of buildings, particularly when combined with insulation.

Shiplap
A traditional profile for horizontal installation only.  The visible bottom edges are square. Available in 100mm & 150mm (Single Plank) and 300mm (Twin Plank ) coverage.

Open V
A modern design forming a castellated effect with a symmetrical V groove which gives a sharper overall appearance to the joints.  May be installed horizontally or vertically.  Ideal for use as a soffit board.

Tee Gee
An almost flush finish profile forming a small V groove at the joint.  This profile may be installed horizontally or vertically.  Ideal for use as a soffit board.

Feather Edge
Mimics the traditional, overlapping feather edge style of cladding, with a rounded bottom edge.  For use in horizontal applications only.

Universal Trims
A range of trims for various edge conditions:
A = Universal Channel
B = Universal Channel & Batten Cover
C = Plank Top
D = 2 Part Universal

Angles
E = 60 x 15mm
F = 30 x 15mm

Corners
G = External
H = 2 Part Corner

Starters
I = Universal
J = Wall
K = Drip
L = Drip Trim

Joints
N = 2 Part Joint
O = Centre Joint
P = Joint Cover

Ventilators
30 x 15mm Angle Ventilator
60 x 15mm Angle Ventilator

A range of decorative  elements for roofline that allow the designer to create an individual feel to a property while retaining the benefits of a standard system.

The range consists of: Fascias & bargeboards, Apex finishes and Decorative trims. The Swish Technical Services team is able to develop bespoke elements where there is a commercial requirement.

All-Dec-Barges.gif

Decorative Bargeboards

There are two Swish systems:
i) Decorative Roofline consists of concave and convex designs in 5m lengths.
ii) Roofstyle is a system of moulded 450mm components (convex & concave) that fit to the face of an existing board.
Spires, Finials & Bracing Bar
These units are essentially decorative and afford a simple but highly effective enhancement to any installation.  Where there is no direct line of sight to the back of the spire, either from ground level or from within the dwelling, a flat-backed spire (C475 or C476) will present a rapid and simple decorative cap to the face of the bargeboard at the apex.

A 3D spire (C466) with detailing to all faces allows the unit to be viewed from all angles.

Dentils

The range meets the requirements of most new build and refurbishment applications as each unit is capable of a secret mechanical fix in at least one direction.

A continuous sub-fascia of cellular PVC fixed to the wall under the soffit will greatly enhance the effect.

Corbel & Gallows Brackets

The Corbel has sharply defined sweeping curves which are most effective when installed below a flat top canopy or used in pairs beneath oriel windows.

Swish Gallows Brackets are load bearing and capable of offering structural support to door and window canopies. The surface pattern mimics the traditional appearance of timber with a high level of bevelling detail.

Trims
A full range of decorative trims that can be used on their own, or in combination, to enhance the look of the installation.

  • Quadrants
  • Angles
  • Cloaking Trims
  • Decorative Trims
Typical applications are at the gable eaves and under the fascia soffit where trims are used to soften the look of the joint between boards and to add appeal to the installation.

Mahogany-Box-End-220x124px.jpg

Mahogany

Light-Oak-Box-End-220x124px.jpg

Light Oak

Black-box-end-220x124px.jpg

Black

A range of roofline cladding and windowboard products is available in colours. Some are achieved by the application of a durable foil finish others are skinned in a coloured PVC material. The appropriate roofline corners, joints and trims are finished in the same materials, ensuring a uniform finish.

Foiled products have the same low-maintenance properties as their white counterparts, requiring the occasional wipe with a damp, soft cloth and mild detergent as necessary.

The foiled range complements many of the window, door and conservatory systems currently in use.
Anthracite-Range150x84.jpg   Grey-Range150x84.jpg   
Anthracite                                     Grey                                           
Rosewood_Range_for-Web_150x84.jpg
Rosewood

Knowledge Tester

The Swish knowledge tester is a multi choice test cover the key points of a roofline installation. To log in simply enter 'guest' in the username and password boxes. Good luck.

Find a Swish Stockist

Stock.jpgTo find a stockist of Swish fascia, soffit, gutter and cladding profiles that will be able to meet your supply needs please contact us:
 
Telephone - 01827 317212 or 01827 317235
 
Email - info@swishbp.co.uk
 